Electrical Wire Buyers Washington, DC & Maryland
Shielded power cable · Washington, DC & Maryland

SELL SURPLUS MEDIUM AND HIGH-VOLTAGE CABLE

Medium-voltage cable is the most heavily engineered conductor on a site, and the least sensible to leave sitting in a yard. We buy surplus 5kV through 69kV shielded cable in EPR and XLPE across Washington, DC and Maryland.

Rows of large wooden cable reels sitting on timber pallets in an outdoor yard

Medium-voltage cable carries power at 5kV and above, usually from a service point or substation to a transformer, switchgear or large motor. The construction is layered: conductor, semiconducting strand shield, EPR or XLPE insulation, insulation shield, a metallic shield of copper tape or wire, and an overall jacket. Many designs add a concentric neutral of copper wires over the shield, and every cable carries an insulation level, 100% or 133%, which states the dielectric margin built in.

Surplus in this class is not like building wire. The reels are few, the lengths long, and the value per reel is real. A project ordered 15kV cable for three feeders and built two; a plant replaced a run with tape-shielded cable where the original was concentric neutral; a contractor over-ordered 1/0 CN by 800 ft when the duct route changed. The reel is too heavy to move casually and too valuable to scrap, so it sits under a tarp.

What we buy

  • 5kV and 8kV cable — plant distribution and older industrial systems, often EPR insulated.
  • 15kV cable — the most common distribution class in this region, in 1/0 through 1000 kcmil copper and aluminum.
  • 25kV and 35kV cable — higher-class feeders, usually jacketed, with heavier insulation walls.
  • 69kV and above — reviewed case by case: the reels are large, the market narrow and documentation matters.
  • EPR and XLPE insulation — including tree-retardant XLPE, in 100% and 133% levels.
  • Shield constructions — copper tape, wire shield, concentric neutral and flat-strap neutral.
  • Jacketed single conductor — full and partial lengths on large wooden reels, plus three-conductor assemblies.

How to read a medium-voltage reel

At this voltage the print carries the engineering, and a partial reel without a legible legend is close to unidentifiable. Start with class, insulation system and shield:

What matters on a shielded power cable reel
DetailWhat to look forWhy it matters
Voltage class5kV, 8kV, 15kV, 25kV, 35kV or 69kV printThe class fixes which equipment the cable can serve
InsulationEPR or XLPE, with the wall thickness statedThe compound and wall thickness set the dielectric rating
Insulation level100% or 133% marking133% cable carries more dielectric margin
ShieldCopper tape, wire shield or concentric neutralThe shield must match the grounding and fault-current design
JacketOverall jacket present, marked and unbrokenThe jacket is the moisture barrier; a breach reaches the shield
LengthFactory tag on the reel flangeLong runs are cut to a duct route, so a matched remainder sells

Condition and length

Shielded cable is less tolerant of storage than anything else on this site. Water is the main enemy: moisture reaching the insulation shield through an open end will travel, and cable stored for years with bare ends in the rain is a different proposition from one with capped ends under cover. Bend radius matters too, because a coil dropped off a lift can damage insulation and shield without a visible mark.

  • Factory reels with tag, class and length readable
  • Ends capped, with the jacket continuous to the cut
  • Covered storage, off the ground
  • 15kV concentric neutral and tape shield reels from closeout
  • Partial reels of several hundred feet or more, measured

We decline cable with jacket cuts that expose the shield, ends left open to weather for years, reels that were crushed or dropped, and any reel whose class cannot be established. A reel of unknown class is a bargain for neither side, and we will say so rather than guess.

Large surplus cable reels loaded on a flatbed trailer for transport
Large reels loaded for transport. At this size the reel is part of the handling problem, so access and weight matter as much as footage.

Splice and termination kits are not wire

We buy cable. The accessories — splice kits, termination kits, stress cones, elbows, loadbreak connectors, grounding kits — are outside what this site purchases, and a lot mixing cable with a pallet of accessories is reviewed on the cable alone.

Describe them separately if a closeout includes both; it saves a round of questions.

What to photograph

  1. The reel flange with the tag, so class and factory length read together.
  2. The jacket print in one unbroken shot; the legend is long and hard to fit in a frame.
  3. Both cable ends, showing whether they are capped or open.
  4. The storage position: on the ground, on dunnage or under cover, and any flange damage that shows how it was handled.

Medium-voltage surplus in Washington, DC and Maryland

Maryland holds the industrial base that generates the larger reels. Baltimore plants run their own 5kV and 15kV distribution and re-cable a line when a transformer is replaced; water and wastewater facilities rework pump station feeders; data center campuses take medium-voltage service and reconfigure as halls are added; and quarries, mills and processing sites outside the Beltway produce 25kV and 35kV reels that are hard to dispose of locally.

FAQ

Frequently asked questions

  • What is the difference between 100% and 133% insulation level?

    The percentage states the dielectric margin built into the cable relative to the system voltage. A 133% cable has a thicker insulation wall and can be applied on systems where the grounding conditions or the specification call for more margin. The marking is printed on the jacket and we read it rather than assume it.

  • Do you buy cable with the ends left open?

    It can be reviewed, but open ends over a long period are a real concern, because moisture travels along the shield and degrades the insulation. Tell us how long the ends have been exposed and photograph them. Capped ends and covered storage always review better.

  • Can you identify cable when the jacket print has faded?

    Sometimes. The reel tag often carries the class and length, and the construction itself — insulation wall, shield type, jacket — can be assessed from a cut end. Without either the print or the tag, the cable is treated as unidentified and is unlikely to be purchased as reusable stock.

  • Do you take splice kits and terminations with the cable?

    No. This site buys wire and cable only. Splice kits, termination kits, elbows and connectors are a separate category and are not part of a cable purchase, so keep them out of the cable lot when you submit it.

Sell your surplus wire

Send the details.
We’ll review the reel.

Tell us what you have and where it sits. Photos of the reel, the jacket legend and the tag do more than a paragraph of description.

+1 (614) 715-3047 saleselectricalbuyers@gmail.com
Serving
Washington, DC and Maryland
Response
Most quote requests are reviewed within one business day.
What to include
Reel photos, markings, size, footage, condition and loading access.
This page
/wire-types/medium-voltage-cable/

Send your reel details

Fields marked * are required. Photos matter most: reel faces, jacket markings and tags.

Your contact details
Five digits, e.g. 21230.
The wire or cable
Photos and details
Select several images at once: overall reel or spool photos, close-ups of cable markings and jacket legends, tags, labels and the cut ends of the wire. Photograph labels flat and in good light. 10 MB total upload limit. Phone photos are often 2–3 MB each, so 3–5 photos usually fit. If you have more, send them to saleselectricalbuyers@gmail.com and mention this submission.

Your contact details and photos are used only to review and respond to this quote request. See our privacy notice. If the form does not send, email the same details and photos to saleselectricalbuyers@gmail.com or call +1 (614) 715-3047.

Sell Your Surplus Wire