SELL SURPLUS MEDIUM AND HIGH-VOLTAGE CABLE
Medium-voltage cable is the most heavily engineered conductor on a site, and the least sensible to leave sitting in a yard. We buy surplus 5kV through 69kV shielded cable in EPR and XLPE across Washington, DC and Maryland.
Medium-voltage cable carries power at 5kV and above, usually from a service point or substation to a transformer, switchgear or large motor. The construction is layered: conductor, semiconducting strand shield, EPR or XLPE insulation, insulation shield, a metallic shield of copper tape or wire, and an overall jacket. Many designs add a concentric neutral of copper wires over the shield, and every cable carries an insulation level, 100% or 133%, which states the dielectric margin built in.
Surplus in this class is not like building wire. The reels are few, the lengths long, and the value per reel is real. A project ordered 15kV cable for three feeders and built two; a plant replaced a run with tape-shielded cable where the original was concentric neutral; a contractor over-ordered 1/0 CN by 800 ft when the duct route changed. The reel is too heavy to move casually and too valuable to scrap, so it sits under a tarp.
What we buy
- 5kV and 8kV cable — plant distribution and older industrial systems, often EPR insulated.
- 15kV cable — the most common distribution class in this region, in 1/0 through 1000 kcmil copper and aluminum.
- 25kV and 35kV cable — higher-class feeders, usually jacketed, with heavier insulation walls.
- 69kV and above — reviewed case by case: the reels are large, the market narrow and documentation matters.
- EPR and XLPE insulation — including tree-retardant XLPE, in 100% and 133% levels.
- Shield constructions — copper tape, wire shield, concentric neutral and flat-strap neutral.
- Jacketed single conductor — full and partial lengths on large wooden reels, plus three-conductor assemblies.
How to read a medium-voltage reel
At this voltage the print carries the engineering, and a partial reel without a legible legend is close to unidentifiable. Start with class, insulation system and shield:
| Detail | What to look for | Why it matters |
|---|---|---|
| Voltage class | 5kV, 8kV, 15kV, 25kV, 35kV or 69kV print | The class fixes which equipment the cable can serve |
| Insulation | EPR or XLPE, with the wall thickness stated | The compound and wall thickness set the dielectric rating |
| Insulation level | 100% or 133% marking | 133% cable carries more dielectric margin |
| Shield | Copper tape, wire shield or concentric neutral | The shield must match the grounding and fault-current design |
| Jacket | Overall jacket present, marked and unbroken | The jacket is the moisture barrier; a breach reaches the shield |
| Length | Factory tag on the reel flange | Long runs are cut to a duct route, so a matched remainder sells |
Condition and length
Shielded cable is less tolerant of storage than anything else on this site. Water is the main enemy: moisture reaching the insulation shield through an open end will travel, and cable stored for years with bare ends in the rain is a different proposition from one with capped ends under cover. Bend radius matters too, because a coil dropped off a lift can damage insulation and shield without a visible mark.
- Factory reels with tag, class and length readable
- Ends capped, with the jacket continuous to the cut
- Covered storage, off the ground
- 15kV concentric neutral and tape shield reels from closeout
- Partial reels of several hundred feet or more, measured
We decline cable with jacket cuts that expose the shield, ends left open to weather for years, reels that were crushed or dropped, and any reel whose class cannot be established. A reel of unknown class is a bargain for neither side, and we will say so rather than guess.
Splice and termination kits are not wire
We buy cable. The accessories — splice kits, termination kits, stress cones, elbows, loadbreak connectors, grounding kits — are outside what this site purchases, and a lot mixing cable with a pallet of accessories is reviewed on the cable alone.
Describe them separately if a closeout includes both; it saves a round of questions.
What to photograph
- The reel flange with the tag, so class and factory length read together.
- The jacket print in one unbroken shot; the legend is long and hard to fit in a frame.
- Both cable ends, showing whether they are capped or open.
- The storage position: on the ground, on dunnage or under cover, and any flange damage that shows how it was handled.
Medium-voltage surplus in Washington, DC and Maryland
Maryland holds the industrial base that generates the larger reels. Baltimore plants run their own 5kV and 15kV distribution and re-cable a line when a transformer is replaced; water and wastewater facilities rework pump station feeders; data center campuses take medium-voltage service and reconfigure as halls are added; and quarries, mills and processing sites outside the Beltway produce 25kV and 35kV reels that are hard to dispose of locally.
Frequently asked questions
What is the difference between 100% and 133% insulation level?
The percentage states the dielectric margin built into the cable relative to the system voltage. A 133% cable has a thicker insulation wall and can be applied on systems where the grounding conditions or the specification call for more margin. The marking is printed on the jacket and we read it rather than assume it.
Do you buy cable with the ends left open?
It can be reviewed, but open ends over a long period are a real concern, because moisture travels along the shield and degrades the insulation. Tell us how long the ends have been exposed and photograph them. Capped ends and covered storage always review better.
Can you identify cable when the jacket print has faded?
Sometimes. The reel tag often carries the class and length, and the construction itself — insulation wall, shield type, jacket — can be assessed from a cut end. Without either the print or the tag, the cable is treated as unidentified and is unlikely to be purchased as reusable stock.
Do you take splice kits and terminations with the cable?
No. This site buys wire and cable only. Splice kits, termination kits, elbows and connectors are a separate category and are not part of a cable purchase, so keep them out of the cable lot when you submit it.
Send the details.
We’ll review the reel.
Tell us what you have and where it sits. Photos of the reel, the jacket legend and the tag do more than a paragraph of description.
+1 (614) 715-3047 saleselectricalbuyers@gmail.com- Serving
- Washington, DC and Maryland
- Response
- Most quote requests are reviewed within one business day.
- What to include
- Reel photos, markings, size, footage, condition and loading access.
- This page
- /wire-types/medium-voltage-cable/