SELL SURPLUS MC AND AC ARMORED CABLE
MC and AC cable are bought in coils, cut short, and left over on almost every interior job. We buy the remainders — 12/2 and 10/3 coil ends, hospital assemblies, full 250 ft coils and sealed 1,000 ft reels — across DC and Maryland.
Metal-clad cable is a factory assembly: THHN or THWN conductors inside a spiral interlocked aluminum armor, made for the places where running conduit would take longer than pulling a listed assembly. It is a 600V product, built with two to four conductors with or without a grounding conductor, and #14 through #2 covers most of what is stocked and installed. AC cable, still called BX, is the close relative with a bonded aluminum ground strip and a paper wrap separating the conductors from the armor.
Surplus is a coil problem. MC is ordered in coils and on reels, a fit-out changes direction or device count, and half a coil goes back in the gang box. Service changes swap 12/2 for 10/2, redesigns drop a branch circuit, and shops that move to a different wiring method end up with sealed coils they will not use. None of that material is damaged. It is simply the wrong length or the wrong configuration for the next job.
What we buy
- MC cable — interlocked aluminum armor, THHN/THWN conductors, 600V, 2, 3 or 4 conductor with or without ground, #14 through #2.
- AC cable (BX) — bonded aluminum ground strip and paper wrap, 600V, most often 2 and 3 conductor.
- Redundant-ground and hospital assemblies — MC built with an additional green grounding conductor for patient care areas.
- Isolated-ground MC — where the conductor count, colours and print are still readable.
- Armor variants — standard interlocked strip armor and the smooth or corrugated armor used where abrasion resistance is specified.
- Coils and reels — part coils from about 25 ft upward, full 250 ft coils and 1,000 ft reels, banded or boxed.
How to read an MC cable coil
Armored cable is hard to identify from a distance, because the armor hides the conductors. The coil tag and the print on the conductors at an exposed end do the work. Open one end far enough to see the conductor count and colours, then photograph the tag.
| Detail | What to look for | Why it matters |
|---|---|---|
| Armor | Interlocked strip, tight and untwisted, no crushed sections | Deformed armor will not pull and cannot be straightened in the field |
| Conductor count | 2/C, 3/C or 4/C, with or without an insulated ground | The ground configuration has to match the next job |
| Size | #14, #12, #10, #8, #6, #4 or #2 AWG | #12 and #10 assemblies in common counts move fastest |
| Insulation print | THHN or THWN, 600V, 90°C dry | A wet-rated conductor broadens where the cable can be installed |
| Product family | MC versus AC/BX with a bonded ground strip | They are different products and are priced separately |
| Length | Coil tag, counter or a measured remainder | Coil ends under about 25 ft are rarely worth handling on their own |
Condition and length
Armor takes abuse in a way that conductor never does. A coil that was dragged across a slab, run over by a cart or bent tighter than its radius will have flattened or separated interlocking, and that damage is permanent. Coils stored dry and upright in a gang box or on a shelf are the easy ones.
- Full coils with the factory band, tag and wrapper in place
- Part coils with a legible tag and armor that still interlocks cleanly
- Sealed 1,000 ft reels of 12/2, 12/3, 10/2 and 10/3
- Hospital and redundant-ground assemblies in usable lengths
- AC cable coils with the paper wrap intact and no crushed sections
We decline coils with unwound or crushed armor, cable that has been installed and pulled back, coils with no identifiable conductor count, and lengths short enough that no one will pull them again. Mixed pallets are welcome, since the good coils can be separated from the rest during review.
What to photograph
- The coil or reel as a whole, with the band or wrapper visible.
- The manufacturer tag, showing type, conductor count and footage.
- An opened end, fanned out, so the conductors and ground are countable.
- Any armor damage, photographed close rather than described.
- The storage shelf or container, so we know how the material has been handled.
Count the conductors before you call it 12/2
A 12/2 MC with a green ground and a 12/2 AC cable look similar on the outside and are not the same product. The fastest way to settle it is a photo of the opened end with the conductors separated. That single image answers count, size, colours, ground type and usually the manufacturer.
MC and AC surplus in Washington, DC and Maryland
District surplus comes from interior work: office and retail fit-outs, restaurant kitchens, rowhouse renovations and basement build-outs where branch circuits were re-routed after framing. Coils get cut for a run that later changed, and the remainder rides around in a van until someone clears it out.
In Maryland the volume is larger and more institutional. Schools and hospitals in Montgomery and Howard counties, apartment buildings across Prince George’s County and Baltimore, and warehouse or laboratory fit-outs all generate coil ends by the pallet. Contractors who standardize on one assembly also dump the odd counts — 4/C, isolated ground, oversized grounds — when a spec changes between phases.
Frequently asked questions
Do you buy part coils of MC cable?
Yes, down to roughly 25 ft on common configurations such as 12/2 and 12/3 with ground. Below that we usually only consider the material as part of a larger lot, because the handling cost outweighs the value of a few feet.
Is AC cable worth the same as MC?
No. AC cable uses a bonded aluminum ground strip rather than an insulated grounding conductor, so it serves a narrower set of jobs. It is still purchased, but on its own terms and usually at a lower value than an equivalent MC assembly.
Can you identify the cable if the tag is gone?
Usually. The conductor print at an exposed end gives size, insulation type and often the manufacturer, and the armor style separates MC from AC. A clear photo of the opened end is normally enough to quote.
Do you take MC that was already installed and removed?
Rarely. Pulled cable is usually kinked, the armor separates at the bends, and the cut lengths are short. We will look at it if the quantity is large and the armor is intact, but removed cable is normally declined.
Send the details.
We’ll review the reel.
Tell us what you have and where it sits. Photos of the reel, the jacket legend and the tag do more than a paragraph of description.
+1 (614) 715-3047 saleselectricalbuyers@gmail.com- Serving
- Washington, DC and Maryland
- Response
- Most quote requests are reviewed within one business day.
- What to include
- Reel photos, markings, size, footage, condition and loading access.
- This page
- /wire-types/mc-ac-cable/