Buying surplus electrical wire · Washington, DC & Maryland +1 (614) 715-3047  ·  saleselectricalbuyers@gmail.com
Electrical Wire Buyers Washington, DC & Maryland
Service entrance cable · Washington, DC & Maryland

SELL SURPLUS SER AND SEU SERVICE CABLE

SER and SEU are short-run products, so surplus tends to arrive in coils rather than reels: a 250 ft coil with 90 ft left, or a service change that was resized after the cable was bought. We buy both styles across DC and Maryland.

Wire spools of white and orange cable resting on a gravel yard

SER is service entrance cable in the round style: two or three insulated conductors plus a bare ground, all wrapped and jacketed into one assembly. SEU is the flat version, where the neutral is a concentric conductor wrapped around the insulated cores and also serves as the ground. Both are 600V products, both are made in aluminum and copper, and both are used for service drops, subpanel feeds and feeder runs where conduit is not wanted. Aluminum SER in 2-2-2-4 and up through 4/0 and larger covers most residential and light commercial work.

Surplus appears when a service calculation changes after the cable is on site. A panel upgrade gets re-engineered to a larger service, a meter location moves, or a crew buys a coil sized for the longest possible run and cuts it once. Because SER is a short-run product, the leftover is rarely huge, but it is also rarely worn out — it usually sat in a truck or on a shelf from the day it was cut.

What we buy

  • SER cable — round assembly, two or three insulated conductors plus a bare ground, 600V.
  • SEU cable — flat assembly with a concentric neutral serving as the ground, 600V.
  • Aluminum SER — 2-2-2-4 and similar configurations from #2 up through 4/0 and larger.
  • Copper SER and SEU — less common in new work, priced on copper content and length.
  • Coils and reel lengths — 125, 250 and 500 ft coils, plus reel lengths from larger service work.
  • Outdoor-rated jackets — sunlight-resistant constructions marked for exterior and mast runs.

How to read a SER or SEU coil

Service cable is identified by its configuration rather than by a single type name. The print reads something like 2-2-2-4 AL SER, and each of those numbers matters: the insulated conductors, then the reduced neutral or ground. Photograph the print and the coil tag together.

Details that decide the value of SER or SEU
DetailWhat to look forWhy it matters
StyleRound SER or flat SEU with a concentric neutralThe two are not interchangeable at the panel
Configuration2-2-2-4, 3-3-3-5, 4/0-4/0-2/0 and similar printsConductor and neutral sizes set the ampacity the cable can serve
MetalAluminum as standard, copper on older and specialty workMetal content drives most of the value
Rating600V, with sunlight-resistant marking for exterior runsOutdoor-rated cable serves a wider set of buyers
LengthCoil tag or a measured remainderService runs are short, so a 90 ft remainder can still sell
JacketIntact outer jacket, dry, no splits at the cut endsA split jacket exposes the bare ground and ends the usable length

Condition and length

SER lives outdoors and in crawl spaces, so jacket condition matters more than it does on indoor building wire. The outer jacket is what keeps the bare ground and the neutral wrap dry. A coil that sat on a truck bed for a season is usually fine. A coil that sat in standing water, or one where the jacket is split for several feet back from the end, is not.

  • Full coils still banded with the factory tag
  • Part coils with a tagged or measured remainder
  • Aluminum SER in 2-2-2-4 and larger configurations
  • Sunlight-resistant SEU from exterior service work
  • Mixed coils from a service crew clearing out a truck

We decline coils with a jacket split back into the assembly, cable that has been pulled through a mast and removed, lengths under about 25 ft, and any coil where the configuration cannot be read. Copper SER with corroded or badly oxidized conductors is also usually declined, since the loss at the terminations cannot be recovered.

Copper electrical wire on wooden reels stored in a gravel storage yard
Service cable and building wire stored in a yard. Coils kept off gravel and under cover keep the jacket intact, which is what preserves the full length of a SER run.

What to photograph

  1. The coil as a whole, with the band, tag and wrapper visible.
  2. The jacket print, showing the configuration and the metal.
  3. The cut end, so the insulated conductors and bare ground can be counted.
  4. Any sunlight-resistant or outdoor marking, shot close.
  5. The cut ends of both coil ends if the cable has been cut twice.

SER and SEU surplus in Washington, DC and Maryland

District surplus is dominated by service changes in older housing stock. Rowhouse and small apartment buildings in Northwest, Northeast and Southeast DC are constantly having panels replaced and services upgraded, and the cable is bought before the meter and mast details are settled. When the service size or the routing changes, a cut coil is left over.

Maryland spreads it wider. Townhouse subdivisions in Prince George’s and Anne Arundel counties generate SER offcuts by the coil, while Frederick, Hagerstown and the Eastern Shore produce SEU from well feeds, barns, outbuildings and detached garages. Those rural runs are long, so the coils are often large and only partly used, and they sit in a shed until someone decides to clear it.

FAQ

Frequently asked questions

  • What is the difference between SER and SEU?

    SER is the round assembly with two or three insulated conductors plus a separate bare ground. SEU is flat, with the neutral wrapped concentrically around the insulated cores and used as the ground. Both are 600V service entrance cable, but they suit different installations and are not interchangeable.

  • Do you buy SER cut to a short length?

    Sometimes. Service runs are short by nature, so a 90 ft remainder is a normal size and can be useful. Under about 25 ft we usually only consider the coil as part of a larger lot.

  • Is copper SER worth more than aluminum?

    Per pound of conductor, yes. In practice, aluminum is far more common for service work in this region, so copper SER tends to be older material and is reviewed for conductor condition as well as length.

  • Can you quote from the print if the tag is gone?

    Yes, in most cases. The configuration, metal and voltage are printed along the jacket, and the outside diameter helps confirm the size. A clear close-up of the print is what we need most.

Sell your surplus wire

Send the details.
We’ll review the reel.

Tell us what you have and where it sits. Photos of the reel, the jacket legend and the tag do more than a paragraph of description.

+1 (614) 715-3047 saleselectricalbuyers@gmail.com
Serving
Washington, DC and Maryland
Response
Most quote requests are reviewed within one business day.
What to include
Reel photos, markings, size, footage, condition and loading access.
This page
/wire-types/ser-seu-cable/

Send your reel details

Fields marked * are required. Photos matter most: reel faces, jacket markings and tags.

Your contact details
Five digits, e.g. 21230.
The wire or cable
Photos and details
Select several images at once: overall reel or spool photos, close-ups of cable markings and jacket legends, tags, labels and the cut ends of the wire. Photograph labels flat and in good light. 10 MB total upload limit. Phone photos are often 2–3 MB each, so 3–5 photos usually fit. If you have more, send them to saleselectricalbuyers@gmail.com and mention this submission.

Your contact details and photos are used only to review and respond to this quote request. See our privacy notice. If the form does not send, email the same details and photos to saleselectricalbuyers@gmail.com or call +1 (614) 715-3047.

Sell Your Surplus Wire