SELL SURPLUS URD AND USE-2 UNDERGROUND CABLE
Underground laterals are ordered by the reel and installed by the foot, so the remainder usually outlives the job. We buy URD and USE-2 cable in aluminum and copper, single conductor or twisted assembly, throughout Washington, DC and Maryland.
URD means underground residential distribution cable: the 600V conductor that runs from a transformer, pedestal or handhole to a meter, a panel or a pole. It is normally aluminum, insulated with cross-linked polyethylene, and built to be buried directly in soil without a conduit. Most of what is sold here carries a dual URD/USE-2 print, so the same conductor can serve as an underground service entrance cable as well as a lateral.
Surplus builds up because underground work is quoted in reel quantities and installed in irregular runs. A plat gets redesigned after the transformer layout changes, a service upgrade finishes forty feet short of the reel, or a crew ends the season with three untouched reels because the next phase was deferred. The material is heavy and awkward to shelve, so it sits in a yard until someone needs the space.
What we buy
- URD single conductor — 600V aluminum, #6 through 1000 kcmil, XLP insulated, rated for direct burial.
- URD triplex and quadruplex — twisted phase and neutral assemblies used for lateral runs and street lighting circuits.
- USE-2 — underground service entrance cable, 90°C wet rated, sunlight resistant, single conductor, direct burial.
- Dual-rated URD/USE-2 — the most common print in the region and the easiest construction to place with another crew.
- Copper URD — less common than aluminum, usually written into a campus or institutional standard, and always worth a look.
- RHH/RHW-2 dual-rated USE-2 — a broader rating that turns up in industrial yard stock more often than in residential work.
- Full and partial reels — factory reels with the tag intact, opened reels with a measured remainder, and short lengths on spools.
How to read a URD reel
Underground cable is a poor candidate for guesswork, because two reels that look identical can carry different insulation compounds and different ratings. Read the print before the tag, then confirm the length:
| Detail | What to look for | Why it matters |
|---|---|---|
| Legend | URD, USE-2, URD/USE-2, XLP or XLPE print | A dual rating lets the next crew use it for a service lateral, not just a run |
| Insulation | Cross-linked polyethylene, or older HMWPE | XLP is the current standard; polyethylene-insulated stock has a narrower market |
| Size | AWG or kcmil, e.g. 2 AWG or 350 kcmil | Value rises steeply above 4/0, where runs are feeders, not laterals |
| Assembly | Single conductor, triplex or quadruplex | An assembly has to match a phase-and-neutral layout to be reusable |
| Voltage | 600V class print | URD is not medium voltage; a shielded 15kV reel is a different product |
| Length | Factory tag, counter reading or your own measure | Crews buy to a run length, so a verified remainder is easier to move |
Condition and length
Cable rated for direct burial is expected to get wet, so rain on a reel is not a defect. What changes the review is mechanical damage and long ultraviolet exposure: jacket that has chalked and crazed, wraps crushed by a forklift fork, a slice through the insulation at the flange, or a reel that stood in a puddle long enough for water to wick into the strands at an open end. How it was stored matters more than how old it is.
- Sealed factory reels with the tag still wired to the flange
- Opened reels where a tape measure or the tag fixes the length
- Triplex and quadruplex assemblies still twisted, with ends capped
- Utility and contractor yard overstock in 350 kcmil and larger
- Copper URD from campus or institutional standards stock
Cable that has already been pulled or buried is normally declined, and so is conductor with a nicked jacket, flattened strands at a kink, or a reel whose length cannot be established. A mixed lot is different: send the whole group and we will separate the usable reels rather than turn down the lot over one bad one.
What to photograph
- The full reel, taken square on, so the flange diameter and the remaining wrap are both visible.
- The jacket legend, shot close enough to read the construction and voltage print.
- The reel tag, including any footage marking and the manufacturer name.
- The cut end, showing the insulation wall, the stranding and whether the end was sealed.
- Where the reel sits, so we can judge truck access and how long it has been outdoors.
URD and USE-2 surplus in Washington, DC and Maryland
District underground work is mostly service replacement and alley reconstruction, so the surplus tends to arrive in small pieces: a few reels of 1/0 and 2/0 aluminum left after a meter bank was re-fed, or a partial reel from a street lighting circuit. Maryland produces the larger volumes. Subdivision phases in Charles, Frederick and Prince George’s counties release reels when a plat is re-engineered, solar site work leaves 350 and 500 kcmil behind, and Eastern Shore crews turn up with a reel or two that exceeded the run.
Distance matters less than people assume. We travel to review material in DC and Maryland, and a trailer load from Salisbury gets the same review as a reel inside the Beltway. What decides it is truck access and whether the lengths are known.
Frequently asked questions
Does URD have to be aluminum?
No. Aluminum is standard because it is lighter and less expensive per foot for the same ampacity, but copper URD exists and is specified for some campus, institutional and utility standards. We review both, and we price copper on its conductor content as well as its reusability.
Do you buy cable that was already installed and pulled out?
Usually not. Pulled cable has been tensioned, bent and often buried, and the jacket damage is not always visible. Short demo lengths are treated as scrap rather than as reusable cable. If a reel was opened but never installed, that is a normal partial reel and worth sending.
Is dual-rated URD/USE-2 worth more than plain URD?
It is easier to place, because the dual print allows the conductor to be used for an underground service entrance as well as a lateral. That flexibility matters to a contractor buying a remainder, and it is one of the first things we check on the jacket.
What if the reel is a 15kV shielded cable that looks similar?
It is a different product with a different review. Shielded medium-voltage cable carries insulation levels, shields and a jacket that URD does not, and it is quoted separately. Send it with the voltage print visible and we will route it to the medium-voltage review.
Send the details.
We’ll review the reel.
Tell us what you have and where it sits. Photos of the reel, the jacket legend and the tag do more than a paragraph of description.
+1 (614) 715-3047 saleselectricalbuyers@gmail.com- Serving
- Washington, DC and Maryland
- Response
- Most quote requests are reviewed within one business day.
- What to include
- Reel photos, markings, size, footage, condition and loading access.
- This page
- /wire-types/urd-use2-cable/